Historic Bodiam Bridge
CINTEC ANCHORS FOR HISTORIC BODIAM BRIDGEArticle reprinted from CONSTRUCTION MAINTENANCE & REPAIR MAY/JUNE 1990 Tim Bilson
History
Presumably this was due to some of the timber piling settling during construction. The cast-iron end bosses of previous ties between the spandrel walls can be seen on both elevations. In 1980 an inspection carried out by divers revealed that the timber piles on which the bridge is founded had become exposed and were deteriorating. In 1982 a concrete filled Fabriform mattress was installed to provide a solid invert and protect the foundations of the bridge. Also in 1982 the approach ramps to the bridge were filled by up to 200mm to minimise the hump. A principal inspection and assessment in 1989 concluded that remedial works to the arch rings and a weight limit of 17 tonnes were required to prevent further deterioration. This weight limit remains in force after the remedial works have been completed to preserve the bridge but will still allow coaches over to visit the adjacent Bodiam Castle, a National Trust property.
This has led to cracking of brickwork adjacent to the arch voussoirs, some movement in the spandrel walls, and delamination of the wing walls at the south end. In view of the historical context of this attractive small bridge, East Sussex County Council was concerned to find an effective means of tying, with minimum visual impact, across the arches, within the thickness of the arch brickwork, CINTEC anchors offered the possibility of bonding along the full length of the anchor without an unsightly external anchorage or problems with grout losses through cracks in the arch. CINTEC anchors The use of CINTEC anchors for Bodiam bridge gives a number of major advantages over conventional cement or resin grouted anchors. Conventional grouted anchor systems can have problems in the grouting, and there are doubts about the effectiveness of the anchors, when large volumes of grout are lost in voids within the structure, or escape throuth cracks. Bodiam bridge, with its cracking and deteriorating joints, provides a good example of the potential problems. But in the case of CINTEC anchors the sleeve limits the travel of the grout and ensures that the holes are filled and effectively bonded to the parent material. This capacity to constrain the grout can be used to tailor the anchor to the material in which it is to be placed; for maximum bond in weak or voided materials a generous sized sleeve of relatively flexible composition can be used with lower grout pressures; in stronger and more homogeneous parent material, a smaller diameter and stiffer sleeve allows higher grout pressures for longer anchor lengths, more economy in grout use and probably greater direct bond. With conventional anchor systems the gap between the tension element and the inner face of the drill hole has to be kept to a minimum to ensure that the hole is completely filled. With a CINTEC anchor the diameter of the drill hole is normally between two and three times the nominal size of the structural section ( and could still be greater) giving a much larger bond area. This is particularly beneficial in weak materials where the low bond stresses combined with the bonding agent maximise the anchorage into the parent material.
With this flexibility it is possible to use the CINTEC system for lengths in excess of five metres, several times the limiting length for some similar systems. The length capability is also a result of using structural hollow sections which can double as the grout tube. This guarantees grout injection at the bottom of the hole without grout tubes and gives confidence that the sleeve is effectively filled. Since the anchors are bonded throughout their length it is quite feasible to stop them behind the exposed face and make good the drill hole with coloured mortar or a slip taken from one of the cores. The solution The smaller anchors were also used for repair of the southern wing walls where core drilling of bulged portions of the wall showed that a half brick facing skin was delaminating from the full 600mm thickness of the wall. The high bond capacity meant that an effective anchorage into a single half-brick skin could be achieved while still having the end of the anchor recessed into the face. Once this skin had been tied back the cavity was grouted to stabilise the bulged area. To complete all the repair work the cracks were surface sealed and grouted with resinous or cementitious grout depending on their width. Brickwork was re-pointed and repaired where this was essential, but this was kept to a minimum because of the difficulty of matching the existing finishes. The Client, who was responsible for the overall design and for construction supervision, awarded the six-week contract to Cavity Lock accredited installer, Brighton based, WT fixings for a sum of 15,000. Design of the sizing and location of the anchors for Cavity Lock Systems Ltd was by the Basildon office of Scott Wilson Kirkpatrick. Previous Page | Home | Bridge Menu | Next Page CINTEC, CINTEC MC Systems, Presstec and Archtec are all Registered Trade Marks, Copyright ©1996-2002 |